Troubleshooting connection issues with PC Meter Connect
Learn how to resolve connection issues with PC Meter Connect .
Products affected: DM50™, DM55™ (K724), DM100, DM125i, DM175i (P725), DM300C™, DM400C™ (G925, G9254, SG925)
Issue
Your franking machine cannot download postage, download software or perform a rate update while connected using PC Meter Connect™.
Cause
Either the franking machine cannot communicate with PC Meter Connect, or PC Meter Connect cannot connect to the Pitney Bowes Data Centre.
Resolution
Solution 1: Check your network configuration
- Make sure that your network is configured to allow the franking machine to communicate with the Pitney Bowes Data Centre.
If your issue is not resolved, try Solution 2.
Solution 2: Try restarting your franking machine
- Unplug your power cord from the back of your franking machine.
- Unplug your USB cable from the back of your franking machine.
- Wait 30 seconds.
- Plug your USB cable back into your franking machine. Make sure that the other end of the USB cable is plugged into your computer.
- Plug your power cord back into your franking machine. You should see the message Meter Detected.
If your issue is not resolved, try Solution 3.
Solution 3: Check to ensure that you have the latest version of PC Meter Connect
- The latest version of PC Meter Connect desktop application is 05.00.0081.
- Right-click on the PC Meter Connect system tray icon (small icons by the clock).
- Select About PC Meter Connect.
- If you do not have the latest version, uninstall and reinstall it:
- Right-click on the system tray icon and select Exit.
- Unplug your USB cable from your franking machine and your computer.
- Unplug your power cord from the back of your franking machine.
- Select Windows Start > Control Panel > Programs and Features.
- Select PC Meter Connect and select Uninstall.
- Download and install the latest version of PC Meter Connect.
- Right-click on the system tray icon and select Exit.
- If PC Meter Connect was reinstalled, restart your franking machine and your computer:
- Unplug your power cord.
- Wait one full minute.
- Plug the power cord directly back into a wall outlet. Check that the wall outlet is working correctly.
- Restart your computer by closing all open programs and selecting Shut down from the Windows Start menu.
- Once your computer has completely shut down, turn it back on.
- Attempt your connection again.
If your issue is not resolved, try Solution 4.
Solution 4: Check the connection between your franking machine and your computer
- Unplug your USB cable from the back of your franking machine, then firmly reconnect it.
- Unplug your USB cable from your computer, then firmly reconnect it.
- If you are using a USB hub, remove your cable from the USB hub and plug it into a USB port on your computer.
- Retry your connection.
- If your connection still fails, try moving your USB cable to a different USB port on your computer.
Recommended: Use a USB port on the back of your computer.
If your issue is not resolved, try Solution 5.
Solution 5: Change the PC Meter Connect Internet options
- Right-click the PC Meter Connect icon in the system tray (small icons by the clock).
- Select Internet Settings.
- Toggle the settings for HTTP Transfer Protocol Method and Protocol. After you make a change, select OK and retest. Try all available combinations. Some options may be disabled depending on the type of franking machine you are using
- HTTP Transfer Protocol Method: Determines whether the data transferred is chunked or non-chunked. Try changing this first, as many firewalls will not allow chunked data by default.
- Protocol: Determines which transfer protocol is used for the data transfer. Many firewalls do not allow FTP.
*Important: Mac, Linux and other non-Windows operating systems are not currently supported. FIPS mode is not currently supported on Windows 10.
If you need further assistance, please contact us.
Related topics
UPDATED: 03 February 2023